upper net_200px.png
upper net_200px.png

ASTM D5882-16 

Compliance Statement

ASTM D5882-16: Standard Test Method for Low Strain Impact Integrity Testing of Deep Foundations

[Link to the ASTM standard] [Compliance certificate (PDF, 194Kb)]

Piletest.com confirms that our PET system, running PET Version 3.00 (or higher) meet, or exceed, the requirements of ASTM Standard D5882-07 (2013).

Specific itemized compliance break-down list:

Item
Description
Requirements
Compliance
5.1.1
Impact force application
Hammer with hard plastic tip
Provided
5.2.1
Calibration accuracy
5%  
Exceeds (1% accuracy)
5.2.1.
Accelerometer linearity
Up to 50 g
Meets
5.2.1.
Accelerometer time constant
≥0.5 sec
Meets
5.2.1.
Resonant frequency
≥ 30 kHz
Meets  
5.3.
Signal transmission
Low-noise shielded cable
Exceeds (Digital transmission + error correction)
5.4.1.
Apparatus
Permanent graphic display
Provided (computer screen)
5.4.1.
Apparatus
Permanent data storage capability
Provided (computer hard disk)
5.4.1.
Apparatus
Blow averaging capability
Provided by software
5.4.1.
Apparatus
Variable amplification
Provided by software
5.4.1.
Apparatus
Filtering capability
Provided by software
5.4.2.
Recording apparatus
12 bit A/D resolution
Exceeds: 24 bits PET Pro USB model 16 bit PET Bluetooth Model
5.4.2.
Sample frequency
25 kHz
Exceeds (50 kHz)
5.4.2.
Clock jitter
≤0.01%
Exceeds
5.4.4.
Signal duration scale
2 L/c plus 5 msec
Exceeds